Highest
output intensity: The Sunspot's 100W lamp delivers
the highest UVA intensity per
lamp watts in the industry. This means that with its >10W/cm2
output, the system will
maximize curing speed without overheating the material being
cured.
Cool Light Output: The unit features a dichroic coated
mirror, which reflects only the useable
UV wavelengths of light through the light guide. The
harmful high temperature infrared is
diverted away from the material being cured. A secondary
in-line filter is utilized to even
further reduce heat for extremely sensitive applications.
Competitors' units in this high
intensity class use only in-line filters, which when used
alone are not as effective. Inadequate
filtering could result in overheating of the object being
cured, and damage of the adhesive
bond line.
Long Lamp Life: The SunSpot's
unique design features provide exceptional lamp life:
1. The lamp is mounted vertically, which allows the arc
to fall straight inline with gravity. This prevents the
arc from wandering into the quartz envelope and overheating
it. This scheme
also insures the arc strikes the conical anode equi-radially,
preventing uneven electrode erosion.
2. The lamp is constructed with an extra-heavy blunt
tipped anode electrode, which does
not degrade quickly over time (like the needle shaped electrodes
of traditional arc lamps).
3. Airflow is carefully channeled to provide symmetrical
cooling of the lamp, which insures
long end seal life, and prevents damaging hot spots and
arc sputtering.
Lamp power regulation: The system’s patented
Power-Plus Lamp Driver maintains
constant lamp power regardless of variations in AC line
input or lamp voltages. This
regulation provides for stable light output, repeatable
curing times, and longer lamp life.
Wide- Range AC line input: The Wide Range 90 to 265
VAC line input makes the SunSpot
easy to use in any country, with no wiring changes or voltage
select switching required.
Timer controlled shutter: The unit features and accurate
1 to 99 second, pedal controlled
exposure timer and shutter. The timer can be switched from
timed to manual for operator
control of curing duration.
Convenient front panel indicators: A front panel hour
meter tracks lamp age, allowing for
consistent lamp replacement scheduling, and a Lamp Ready
LED notifies the user when
warm-up is complete.
Quick-change lamp: The system's side lamp access panel
is removed by loosening a single
thumbscrew, making lamp or reflector changes possible in
1 to 2 minutes.
Forced air cooling: The quiet DC fan cooling system
directs air to critical system
components, insuring cool operation and high system reliability.
|